Welcome to my website - I am glad you are here, and hope you come back often. In the meantime site is under construction but you can find daily new posts . Feel free to surf around and see if you like what's on my site. This site was borned for copier's hobbist ,tehnicians and more. This will serve as an informative location for your business to solve fast and faithful your issues about Minolta copiers. Here you can find, post and talk about all Minolta or KonicaMinolta copiers and printers.

From security reasons your questions and answers do not appear on site but only by mail. Thank you for visit and come back soon.

Recent News

trouble code list minolta cf1501/2001

C0000 Main Motor

s failure to turn The Main Motor Lock signal remains faulty for a predeterminedsss failuress failure to turns failure to turns failure to turns failure to turn

C0060 Fusing Drive Motor

to turn

A Fusing Drive Motor Lock signal remains faulty for a

predetermined continuous period of time while the

Fusing Drive Motor is turning.

C0061 Fusing Drive Motor turning

at abnormal timing

The Fusing Drive Motor Lock signal remains faulty

for a predetermined continuous period of time while

the Fusing Drive Motor remains stationary.

C0094 2nd Image Transfer Roller

pressure/retraction failure

s failure

is not activated (retracted position) within 1 sec.

after the 2nd Image Transfer Roller has started its

retracting motion.

The 2nd Image Transfer Pressure Position Sensor

is not deactivated (not the retracted position)

within 1 sec. after the 2nd Image Transfer Roller

has started its pressing motion.

C0096 1st Image Transfer Roller

pressure/retraction failure

The 2nd Image Transfer Pressure Position Sensor

is not activated (retracted position) within 3

sec. after the 1st Image Transfer Pressure/Retraction

Motor has started turning.

The 1st Image Transfer Retraction Position Sensor

is not deactivated (pressed position) within 1.5

sec. after the 1st Image Transfer Pressure/Retraction

Motor has started turning.

C0098 Fusing Roller pressure/

retraction failure

The 1st Image Transfer Retraction Position Sensor

after the lapse of 0.5 sec. after the Fusing Pressure/

Retraction Motor has started turning for

retraction direction during retraction control.

No change is observed in the encoder pulse even

after the lapse of 0.5 sec. after the Fusing Pressure/

Retraction Motor has started turning for pressure

direction during pressure control.

No change is observed in the encoder pulse even

(pressed position) even when 31 motor

encoder pulses have been counted after the Fusing

Pressure/Retraction Motor has started turning

for pressure direction during pressure control.

C0200 Cyan PC Drum Charge

Corona malfunction

The SCD signal remains inactive for a continuous 1-

sec. period while charge corona is being output (i.e.,

the Remote signal is being turned ON).

C0202 Magenta PC Drum Charge

Corona malfunction

The SCD signal remains inactive for a continuous 1-

sec. period while charge corona is being output (i.e.,

the Remote signal is being turned ON).

C0204 Yellow PC Drum Charge

Corona malfunction

The SCD signal remains inactive for a continuous 1-

sec. period while charge corona is being output (i.e.,

the Remote signal is being turned ON).

C0206 Black PC Drum Charge

Corona malfunction

The SCD signal remains inactive for a continuous 1-

sec. period while charge corona is being output (i.e.,

the Remote signal is being turned ON).

Code Description Detection Timing

The Fusing Pressure Position Sensor is not activated

C0400 Exposure Lamp

turn ON

A Lamp-Out Detection signal is ON after the lapse of

5 sec. after the Exposure Lamp has been turned ON.

C0410 Exposure Lamp turning

ON at abnormal timing

CCD Sensor outputs are written in line RAM at the

end of a scan job and the average of these readings

exceeds a predetermined value.

C0500 Heating Roller warm-up

failure

(Fusing Thermistor 1)

s failure to

temperature and the warm-up cycle is not

completed within the period of 9 min. 10 sec. after

the warm-up cycle has been started.

Fusing Thermistor 1 does not detect a predetermined

rise to a level more than the predetermined output

value within 30 sec. after the warm-up cycle has

started.

C0501 Lower Fusing Roller

Heater Lamp warm-up failure

(Fusing Thermistor 2)

The temperature of Fusing Thermistor 1 does not

reach 100

cycle has started.

The temperature of Fusing Thermistor 2 does not°C within 180 sec. after the warm-up

rise to a level more than the predetermined output

value within 130 sec. after the warm-up cycle has

started.

C0510 Heating Roller abnormally

low temperature

(Fusing Thermistor 1)

The temperature of Fusing Thermistor 1 does not

below 120

state.

The temperature of Fusing Thermistor 1 remains°C for 1 sec. or more in the standby

below 130

cycle.

The temperature of Fusing Thermistor 1 remains°C for 1 sec. or more during a print

below 90

Saver mode.

C0511 Lower Fusing Roller

Heater Lamp abnormally

low temperature

(Fusing Thermistor 2)

The temperature of Fusing Thermistor 1 remains°C for 1 sec. or more in the Energy

below 100

state.

The temperature of Fusing Thermistor 2 remains°C for 1 sec. or more in the standby

below 100

cycle.

The temperature of Fusing Thermistor 2 remains°C for 1 sec. or more during a print

below 100

Saver mode.

C0520 Heating Roller abnormally

high temperature

(Fusing Thermistor 1)

The temperature of Fusing Thermistor 1 remains

above 220

C0521 Lower Fusing Roller

Heater Lamp abnormally

high temperature

(Fusing Thermistor 2)

The temperature of Fusing Thermistor 2 remains

above 190

Code Description Detection Timing

The temperature of Fusing Thermistor 2 remains°C for 1 sec. or more in the Energy°C for 1 sec. or more at all times.°C for 1 sec. or more at all times.

C0650 Scanner Home Sensor

malfunction

Scanner at its home position though the Scanner

is so located.

The Scanner Home Sensor fails to detect the

Scanner though the motor has been energized to

move the Scanner over the maximum distance.

The Scanner Home Sensor fails to detect the

its home position though the Scanner has moved

5 mm away from the home position.

C0660 Scanner overrun failure The Scanner Home Sensor detects the Scanner at

its home position during a period from when the

prescan command and scan preparation command

have been executed to when home return command

is executed.

C0990 LCC Lift-Up Motor malfunction

See the relevant Option Service Manual.

C0991 LCC Lift 1 ascent motion

failure

C0995 LCC Transport Motor malfunction

C0999 LCC Lift 2 ascent motion

failure

C0B00 Finishing option transport

drive malfunction

C0B20 Stapling Unit CD drive

malfunction

C0B30 Finishing option Paper

Aligning Bar moving mechanism

malfunction

C0B48 Finishing option Exit Roll

pressure/retraction failure

C0B4A Finishing option Storage

Roller pressure/retraction

failure

Code Description Detection Timing

The Scanner Home Sensor detects the Scanner at

C0B50 Finishing option stapling

mechanism 1

See the relevant Option Service Manual.

C0B54 Finishing option stapling

mechanism 2

C0B73 Finishing option punch

cam motor mechanism

malfunction

C0B78 Finishing option punch

selector motor mechanism

malfunction

C0B80 Finishing option Shift

Motor mechanism malfunction

C0BA0 Finishing option Elevator

Tray drive failure

C0F30 Abnormally low toner density

detected by Cyan

ATDC Sensor

Toner density that is 2 % or more lower than the target

level is detected ten consecutive times during a

print cycle, ATVC, or image stabilization sequence.

C0F31 Abnormally high toner

density detected by Cyan

ATDC Sensor

Toner density that is 4 % or more higher than the target

level is detected ten consecutive times during a

print cycle, ATVC, or image stabilization sequence.

C0F32 Abnormally low toner density

detected by Magenta

ATDC Sensor

Toner density that is 2 % or more lower than the target

level is detected ten consecutive times during a

print cycle, ATVC, or image stabilization sequence.

C0F33 Abnormally high toner

density detected by

Magenta ATDC Sensor

Toner density that is 4 % or more higher than the target

level is detected ten consecutive times during a

print cycle, ATVC, or image stabilization sequence.

C0F34 Abnormally low toner density

detected by Yellow

ATDC Sensor

Toner density that is 2 % or more lower than the target

level is detected ten consecutive times during a

print cycle, ATVC, or image stabilization sequence.

C0F35 Abnormally high toner

density detected by Yellow

ATDC Sensor

Toner density that is 4 % or more higher than the target

level is detected ten consecutive times during a

print cycle, ATVC, or image stabilization sequence.

C0F36 Abnormally low toner density

detected by Black

ATDC Sensor

Toner density that is 2 % or more lower than the target

level is detected ten consecutive times during a

print cycle, ATVC, or image stabilization sequence.

C0F37 Abnormally high toner

density detected by Black

ATDC Sensor

Toner density that is 4 % or more higher than the target

level is detected ten consecutive times during a

print cycle, ATVC, or image stabilization sequence.

C0F3A Cyan ATDC Sensor

adjustment failure

Cyan ATDC Sensor adjustment does not function

properly, failing to adjust to an appropriate value.

C0F3B Magenta ATDC Sensor

adjustment failure

Magenta ATDC Sensor adjustment does not function

properly, failing to adjust to an appropriate value.

C0F3C Yellow ATDC Sensor

adjustment failure

Yellow ATDC Sensor adjustment does not function

properly, failing to adjust to an appropriate value.

Code Description Detection Timing

C0F3D Black ATDC Sensor

adjustment failure

Black ATDC Sensor adjustment does not function

properly, failing to adjust to an appropriate value.

C13C8 New Transfer Belt Unit

resetting failure

The output from the new unit detecting terminal

remains HIGH and the copier does not recognize

that a new unit has been installed.

1. After an image stabilization sequence is completed,

the fuse blowout signal of the new unit is

set to a blowout state.

2. After the lapse of 2 sec. after step 1, the fuse

blowout signal is brought to a state where no

new units are installed.

3. After the lapse of 0.1 sec. after step 2, a new unit

check sequence is carried out.

A total of three cycles of steps 1 to 3 are carried out

and, if the copier fails to detect a new unit a third

time, a malfunction condition results.

C13CA New Fusing Unit resetting

failure

The output from the new unit detecting terminal

remains HIGH and the copier does not recognize

that a new unit has been installed.

1. The fuse blowout signal of the new unit is set to a

blowout state.

2. After the lapse of 0.5 sec. after step 1, the fuse

blowout signal is brought to a state where no

new units are installed.

3. After the lapse of 0.1 sec. after step 2, a new unit

check sequence is carried out.

A total of two cycles of steps 1 to 3 are carried out

and, if the copier fails to detect a new unit a second

time, a malfunction condition results.

C13CB New Fusing Web Unit

resetting failure

The output from the new unit detecting terminal

remains HIGH and the copier does not recognize

that a new unit has been installed.

1. The fuse blowout signal of the new unit is set to a

blowout state.

2. After the lapse of 0.5 sec. after step 1, the fuse

blowout signal is brought to a state where no

new units are installed.

3. After the lapse of 0.1 sec. after step 2, a new unit

check sequence is carried out.

A total of two cycles of steps 1 to 3 are carried out

and, if the copier fails to detect a new unit a second

time, a malfunction condition results.

Code Description Detection Timing

C13CC New Oil Coating Unit

resetting failure

The output from the new unit detecting terminal

remains HIGH and the copier does not recognize

that a new unit has been installed.

1. The fuse blowout signal of the new unit is set to a

blowout state.

2. After the lapse of 0.5 sec. after step 1, the fuse

blowout signal is brought to a state where no

new units are installed.

3. After the lapse of 0.1 sec. after step 2, a new unit

check sequence is carried out.

A total of two cycles of steps 1 to 3 are carried out

and, if the copier fails to detect a new unit a second

time, a malfunction condition results.

C13D1 Cyan IU EEPROM failure EEPROM access error:

When EEPROM access control is executed, setting

1

even after the lapse of a predetermined period of

time.

C13D2 Magenta IU EEPROM failure

EEPROM access error:

When EEPROM access control is executed, setting

1

even after the lapse of a predetermined period of

time.

C13D3 Yellow IU EEPROM failure EEPROM access error:

When EEPROM access control is executed, setting

1

even after the lapse of a predetermined period of

time.

C13D4 Black IU EEPROM failure EEPROM access error:

When EEPROM access control is executed, setting

1

even after the lapse of a predetermined period of

time.

C3310 CCD clamp/gain adjustment

failure

Start Flagof GA register does not become readyStart Flagof GA register does not become readyStart Flagof GA register does not become readyStart Flagof GA register does not become ready

(AVE1 - AVE2) =< 4

When clamp adjustment is made:

The average of CCD Sensor output values is 1 or

less.

Dgain = 0

Dgain = 255

C3700 IR Cooling Fan Motor 1

turning at abnormal timing

A Lock signal is detected ten consecutive times

when it is monitored at 0.01-sec. intervals while a

Fan Motor ON signal is being output and, at the

same time, after the lapse of 2 sec. or more after the

output of the Fan Motor ON signal has been started.

Code Description Detection Timing

When gain adjustment is made:

C3710 IR Cooling Fan Motor 2

turning at abnormal timing

A Lock signal is detected ten consecutive times

when it is monitored at 0.01-sec. intervals while a

Fan Motor ON signal is being output and, at the

same time, after the lapse of 2 sec. or more after the

output of the Fan Motor ON signal has been started.

C3720 Original Glass Cooling Fan

Motor turning at abnormal

timing

A Lock signal is detected ten consecutive times

when it is monitored at 0.01-sec. intervals while a

Fan Motor ON signal is being output and, at the

same time, after the lapse of 2 sec. or more after the

output of the Fan Motor ON signal has been started.

C3A00 PIC communication error

predetermined period of time after IREQ has been

received during AIDC sampling of image stabilization

sequence or registration adjustment.

A sampling lock is not received after the lapse of a

between the PIC Board and Master Board.

There is an open-circuit in the communication harness

C3A01 PIC Board malfunction The PIC Board is faulty.

C3FFF ROM contents fault

detected upon start

The system fails to rewrite flash memory during

updating.

Either the PIC Board or Master Board is faulty.

continuous period of time while the Main

Motor is turning.

C0001 Main Motor turning at

abnormal timing

The Main Motor Lock signal remains faulty for a predetermined

continuous period of time while the Main

Motor remains stationary.

C0010 Imaging Unit Motor C

failure to turn

The Lock signal remains faulty for a continuous 1-

sec. period after the motor rotation has stabilized

and before the motor starts decelerating.

C0011 Imaging Unit Motor C turning

at abnormal timing

The Lock signal remains faulty for a continuous 1-

sec. period after the motor has completely stopped

and before the motor starts accelerating.

C0012 Imaging Unit Motor M

failure to turn

The Lock signal remains faulty for a continuous 1-

sec. period after the motor rotation has stabilized

and before the motor starts decelerating.

C0013 Imaging Unit Motor M turning

at abnormal timing

The Lock signal remains faulty for a continuous 1-

sec. period after the motor has completely stopped

and before the motor starts accelerating.

C0014 Imaging Unit Motor Y

to turn

The Lock signal remains faulty for a continuous 1-

sec. period after the motor rotation has stabilized

and before the motor starts decelerating.

C0015 Imaging Unit Motor Y turning

at abnormal timing

The Lock signal remains faulty for a continuous 1-

sec. period after the motor has completely stopped

and before the motor starts accelerating.

C0016 Imaging Unit Motor Bk

failure to turn

The Lock signal remains faulty for a continuous 1-

sec. period after the motor rotation has stabilized

and before the motor starts decelerating.

C0017 Imaging Unit Motor Bk

turning at abnormal timing

The Lock signal remains faulty for a continuous 1-

sec. period after the motor has completely stopped

and before the motor starts accelerating.

C0040 Fusing Cooling Fan Motor

2

A Fusing Cooling Fan Lock signal is detected for a

continuous 3-sec. period while Fusing Cooling Fan

Motor 2 is turning.

C0046 Fusing Cooling Fan Motor

1

A Fusing Cooling Fan Lock signal is detected for a

continuous 3-sec. period while the Fusing Cooling

Fan Motor is turning.

C004C Ozone Ventilation Fan

Motor

An Ozone Fan Lock signal is detected for a continuous

3-sec. period while the Ozone Ventilation Fan

Motor is turning.

C004E Power Supply Cooling Fan

Motor

A Power Supply Cooling Fan Lock signal is detected

for a continuous 3-sec. period while the Power Supply

Cooling Fan Motor is turning.

Recent Comments

  • admin: In service mode (stop,0,stop,1)press 2, start, — “C-”appear, press 5,–C5...
  • peter: how reset drumunit minolta ep 1050? gr peter
  • selahattin: hello I always can help you with Minolta copier me mail about the problem you just throw ara
  • selahattin: hello Your e-mail me please breakdown code error list
  • KattyBlackyard: Hi, interest post. I’ll write you later about few questions!

Services

Copier's chip reseter at cheapest price, valuable information about copier's trouble ,service docummentation (service manuals, parts manuals, service bulletins) for all minolta and konicaminolta products -at request .

Why Hire Us

Quick and cheap competent information about all minolta products

Digital Copier B/W

In this is an area on my website you can find answers for more problems about B/W digital copiers.
Continue reading »

Digital Color Copier

In this is an area on my website you can find answers for more problems about Color digital copiers.
Continue reading »

Color printer #3

TIn this is an area on my website you can find answers for more problems about color printers.
Continue reading »