HOW TO:
fusing unit reset:
- turn of the main switch
- remove the fusing unit
- remove the left cover of the fusing unit
- change the old fuse (green resistor) with 80mA new fuse
- put back the cover andthe fusing unit
turn on the machine
transfer unit reset:
to reset use a new 80 mA glass fuse