bizhub c451,c 550,minolta c650 trouble
March 28, 2009
Jam in DF611:
-on 2-nd side:
Check mylar on the 2nd transport guide plate.
Replace the damaged mylar p/n : 9J07 4703 01
-on 1st side:
- put the tension spring of feed roller in lower position.
- ckech the sensors inside DF611 case and use some adhesive (super glue, super bond) so that the sensors cases will be hard-set.
P21 warning :
- color shift in main scan direction
the amount of color shift is different between front and back side. Color shift occurs at 1 to 2 mm in the worst position.
bizhub C650/C550/C451 (FW Ver.6B only)
The problem will be observed when below 2 conditions meet. However it is not always but it depends on the gain of image density sensor (IDC).
1. When MFP returns from sleep mode within 8 hours from the last image stabilization.
2. In case MFP detects temperature change in printer head at more than 2 degrees from the last regist control when returning from sleep mode.
<Cause>
Regist control, which takes place in above condition, is carried out with improper sensor gain setting.
- P-21 is displayed when the sensor gain is low for the MFP to detect toner pattern.
- Color shift occurs when MFP miss-detect toner pattern due to improper gain setting.
How to recover the problem:
-Apply FW Ver.6M or later
- Turn off/on the main switch
- Carrying out image stabilization