c0700 on minolta di350, di250
June 3, 2009
-toner motor is unable to rotate the toner bottle= The most likely cause is wrong pointing of toner bottle
Solving:
turn of the copier, pull out the toner bottle(don’t rotate the bottle
turn on the copier :
1. hear the noise behind the copier then- c0700 = the toner motor or toner rotate mechanism was broken -you must change the toner rotate mechanism or change all (motor +mechanism) with a new toner motor from EP 1050/1054-it works perfect.
2. c 0700 code appears immediately : first -check and repair the toner rotate mechanism-see above-
:second- replace the blowed 1A fuse on PWB-A with new one
turn on the copier — everything seems ok ? insert toner bottle in correct position
bizhub 250/350 code c2557
April 25, 2009
Troubleshooting for bizhub 250/350 are generally the same like DI250/350 the major difference is this code : 2557
Code usually appears when the meter count of drum and developer (in service mode) was reseted without changing deleloper followed by F8.
how to reset:
-the simplest way is to change developer and run F8.
-without change the developer:
—First : add a spoon of toner in dev. unit and instantly run F8.
—Second (if first way was not good) : in service mode-level history-atdc,There you will see displayed the current value of ATDC. Usually this value should be approximately 13 %, but after resseting it becomes 5-6 % and comes into contradiction with the presetting value in tech rep choice-printer- ATDC gain (155).
So, increase the concentration of toner in developing unit adding little amount of toner or decrease or increase the default value (in tech rep choice-printer - ATDC gain) to match the actual concentration in developing unit.
bizhub 420 code reset-service mode
April 22, 2009
how to enter in service mode when error code appear?
turn of the copier -main switch.
press and hold utility key and turn on the copier and still hold utility key until "trouble reset "appear on the screen.
now you can enter in service mode (without uti/counter,details), only code
minolta di2510 drum reset
April 4, 2009
How to reset PC drum or imaging unit:
Enter in service mode (you already know that procedure),counter, PM , select PC/drum life, press clear key, exit from service menu- do not press reset panel key.
Life expectation-in good condition-of Minolta Di2510/di3510 drum is about 150.000 copies.
bizhub c451/550/minolta c650 parts reset
March 28, 2009
HOW TO:
fusing unit reset:
- turn of the main switch
- remove the fusing unit
- remove the left cover of the fusing unit
- change the old fuse (green resistor) with 80mA new fuse
- put back the cover andthe fusing unit
turn on the machine
transfer unit reset:
to reset use a new 80 mA glass fuse

bizhub c451,c 550,minolta c650 trouble
March 28, 2009
Jam in DF611:
-on 2-nd side:
Check mylar on the 2nd transport guide plate.
Replace the damaged mylar p/n : 9J07 4703 01
-on 1st side:
- put the tension spring of feed roller in lower position.
- ckech the sensors inside DF611 case and use some adhesive (super glue, super bond) so that the sensors cases will be hard-set.
P21 warning :
- color shift in main scan direction
the amount of color shift is different between front and back side. Color shift occurs at 1 to 2 mm in the worst position.
bizhub C650/C550/C451 (FW Ver.6B only)
The problem will be observed when below 2 conditions meet. However it is not always but it depends on the gain of image density sensor (IDC).
1. When MFP returns from sleep mode within 8 hours from the last image stabilization.
2. In case MFP detects temperature change in printer head at more than 2 degrees from the last regist control when returning from sleep mode.
<Cause>
Regist control, which takes place in above condition, is carried out with improper sensor gain setting.
- P-21 is displayed when the sensor gain is low for the MFP to detect toner pattern.
- Color shift occurs when MFP miss-detect toner pattern due to improper gain setting.
How to recover the problem:
-Apply FW Ver.6M or later
- Turn off/on the main switch
- Carrying out image stabilization
minolta cf9001
March 27, 2009
- Old product “oldies but goldies “:
- Minolta CF9001 and Minolta CF910:
- undifferntiated,aleatory and recurrent trouble codes just after power on : check, clean or CHANGE main relay p/n 9341221021.
- white dots on magenta :change the magenta starter
- blue background in middle of the page :
in service mode, counter, life, check the drum’s life : if life reached on 20.000 -change the drum and cleaning blade ,reset counter life for both.- 4 .white strips : in service mode test mode -halftone –print C,M,Y,K test: If the white strips are in same arrangement :
-clean or change corona wire of transfer corona unit (inside of transfer drum)
-clean (use water and soap -no alcohol)- grid of drum charging corona
-remove and clean mirror’s box and laser path on the right side of the copier .
minolta di350 reset all counters
March 21, 2009
In this mode you can reset all counters to 0.
How to reset all couters:
follow the procedure for reset trouble code (insert a paper clip into a small hole situated on the right side of the control panel).
The copier will be restarted.
when a small black dot is on the screen- press 3 key.
Now, in this menu press total clear tab.
di2510/di3510 trouble
March 5, 2009
abort code and restart after power-up:
-check if the CF card is inserted properly
-if CF card it’s, OK -need to reset BRAM:
next to CF card are INI jumpers.
-turn off the machine, pull the jumpers off and cross the pins to the far right and the middle in the verticale direction.
-power ON for 20 seconds then power off.
-remove jumpers and put them back in the original position.
power on.
How to reset C0500 code :
- open the right door
-in the small hole on the right side of the control panel(same as DI 350,di351)press the soft initialization
- When the dot appears on the LCD after reboot, press 3 key.
-enter the service code (default 0000000)
- The mode will change to the initialization screen.
-Choose trouble reset.
-after reboot close the right door
-if same trouble appear again- check the thermal fuse or thermistors(heat sensing elements) or replace the fusing unit.
Light copy on ADF (DF):
-clean with alcohol the optical unit (original glass, mirrors, lamp, lens)
-use the two screws in rear side of DF to correct the position of DF againts original glass.
-pull out the imaging unit and clean the frame glass of laser unit.
-still light copies? but print it’s OK - clean the CCD sensor (only for tech.rep.)
dialta di350, minolta di350 trouble
March 1, 2009
-how to imaging unit reset :
remove he imaging unit, remove the conector -in back of the IU.
in back of the conector you will see a black thin duct - inside this- a green resistor (in fact fuse)
Cut this resistor so that …..see more
How to trouble Co500 reset :
in the right side on control panel, beside LCD contrast currsor is situated a small hole .
insert a pick in this hole until copier will be restarted, then….
see more…