di2510/di3510 trouble
March 5, 2009
abort code and restart after power-up:
-check if the CF card is inserted properly
-if CF card it’s, OK -need to reset BRAM:
next to CF card are INI jumpers.
-turn off the machine, pull the jumpers off and cross the pins to the far right and the middle in the verticale direction.
-power ON for 20 seconds then power off.
-remove jumpers and put them back in the original position.
power on.
How to reset C0500 code :
- open the right door
-in the small hole on the right side of the control panel(same as DI 350,di351)press the soft initialization
- When the dot appears on the LCD after reboot, press 3 key.
-enter the service code (default 0000000)
- The mode will change to the initialization screen.
-Choose trouble reset.
-after reboot close the right door
-if same trouble appear again- check the thermal fuse or thermistors(heat sensing elements) or replace the fusing unit.
Light copy on ADF (DF):
-clean with alcohol the optical unit (original glass, mirrors, lamp, lens)
-use the two screws in rear side of DF to correct the position of DF againts original glass.
-pull out the imaging unit and clean the frame glass of laser unit.
-still light copies? but print it’s OK - clean the CCD sensor (only for tech.rep.)
Comments
One Response to “di2510/di3510 trouble”
Got something to say?


[...] di2510/di3510 trouble [...]