dialta di152 trouble
March 1, 2009
how to maintenance code reset :
utillity-stop -0-0-stop- 01-3-start-3-start-3-start.on display will be apear 00 .Press now ‘clear’ key .on display will be apear 40000 .Touch ’start’ and reset panel .That’s it !
code J– reset :
open the right door- check tension spring and lever’s movement in right side of the fusing unit . The tension spring is usualy too weak , so change it with new one , more strong. Then clean sensor and check correct highness of actuator(in sensor frame). If the actuator is too down -loosen screws of fusing unit , push up the fusing unit-in right side and tight screws.
Fix minolta di 152, minolta di 183 in same way.
spilling toner from imaging unit :
-remove the imaging unit ond open it in usual mode.
-remove the cover of the developing unit
-check in right (back) side of magnet roller -condition of the mylar .If is broken change it with a new one .you cane made new one from thin OHP film.Insert it under doctor blade and put here some adhesive (super bond, super glue). Meantime clean charging corona , charging grid , and replace drum in was broken from old mylar.Check also or replace the roll :

4163-5298-01
Fix minolta di 152, minolta di 183,,minolda di1611, minolta di2011, bizhub 162,bizhub 163 ,bizhub210 in same way.
how to fix cleaner unit : ….soon