minolta cf9001
March 27, 2009
- Old product “oldies but goldies “:
- Minolta CF9001 and Minolta CF910:
- undifferntiated,aleatory and recurrent trouble codes just after power on : check, clean or CHANGE main relay p/n 9341221021.
- white dots on magenta :change the magenta starter
- blue background in middle of the page :
in service mode, counter, life, check the drum’s life : if life reached on 20.000 -change the drum and cleaning blade ,reset counter life for both.- 4 .white strips : in service mode test mode -halftone –print C,M,Y,K test: If the white strips are in same arrangement :
-clean or change corona wire of transfer corona unit (inside of transfer drum)
-clean (use water and soap -no alcohol)- grid of drum charging corona
-remove and clean mirror’s box and laser path on the right side of the copier .